S02-02-02-01 CABLE JOINTING & TERMINATIONS TERMINATION-HEATSHRINK OUTDOOR 22KV-COPPER SCREENED ASSEMBLY DETAIL (2.0 MB) 5 04/2019
S02-02-02-02 CABLE JOINTING & TERMINATIONS TERMINATION-HEATSHRINK OUTDOOR 11KV-BELTED SCREENED ASSEMBLY DETAIL (2.0 MB) 4 04/2019
S02-02-02-03 TERM. 3 CORE BELTED 6.3/11KV &12.7/12KV INDOOR (86.9 KB) 4 02/2005
S02-02-02-05 TERM INDOOR BUSHING TYPE ASSEMBLY DETAILS (1.5 MB) 5 02/2020
S02-02-02-08 HEATSHRINK OUTDOOR LV PAPER LEAD 3.5 CORE ASS. DETAIL (2.4 MB) 3 04/2019
S02-02-02-09 HEATSHRINK INDOOR LV PAPER LEAD 3.5 CORE ASS. DETAIL (1.9 MB) 3 04/2019
S02-02-02-11 REPAIR INSTRUCTIONS SHEATH AND JACKET (2.5 MB) 4 04/2019
S02-02-02-12 JOINTING INSTRUCTIONS LV XLPE (2.3 MB) 3 04/2019
S02-02-02-14 JOINTING INSTRUCTIONS COPPER CONTROL (1.9 MB) 8 07/2021
S02-02-02-15 RAYCHEM PREPARATION INSTRUCTIONS 11/22KV XLPE (2.3 MB) 2 04/2019
S02-02-02-16 RAYCHEM JOINTING INSTRUCTIONS (2.8 MB) 2 04/2019
S02-02-02-17 CABLE JOINTING AND TERMINATIONS WHITE ANT RESISTANT JOINT BOX AND COMPRESSION LINKS 11 22KV XLPE CABLES (70.6 KB) 3 07/2021
S02-02-02-18 JOINT CABLE LV 185SQ MM ALUMINIUM SINGLE CORE XLPE (2.1 MB) 3 07/2021
S02-02-02-23 CABLE JOINTING & TERMINATIONS SIGMAFORM JOINTING INSTRUCTIONS (SHEET 1 OF 2) 11/22KV XLPE CABLE1 (206.7 KB) 1 12/2012
S02-02-02-24 CABLE JOINTING & TERMINATIONS SIGMAFORM JOINTING INSTRUCTIONS (SHEET 2 OF 2)11/22KV XLPE CABLE1 (192.6 KB) 1 12/2012
S02-02-02-25 RAYCHEM JOINTING INSTRUCTIONS 11/22KV XLPE (220.7 KB) 2 12/2012
S02-02-02-26 RAYCHEM JOINTING INSTRUCTIONS 11/22KV XLPE SHEET 2 OF 2 (SHEET 1 REF S02-02-02-25) (177.5 KB) 2 12/2012
S02-02-02-27 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS11KV 3C 300SQ.MM SCREENED PILC TO 11KV 3X1C 240SQ.MM XLPE (179.1 KB) 1 12/2012
S02-02-02-28 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C 300SQ.MM SCREENED PILC TO 11KV 3X1C 240SQ.MM XLPE (224.0 KB) 1 12/2012
S02-02-02-29 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C 300SQ.MM SCREENED PILC TO 11KV 3X1C 240SQ.MM XLPE (190.2 KB) 1 12/2012
S02-02-02-30 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C 400SQ.MM SCREENED PILC TO 11KV 3X1C 400SQ.MM XLPE (183.4 KB) 1 12/2012
S02-02-02-31 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C 400SQ.MM SCREENED PILCTO 11KV 3X1C 400SQ.MM XLPE (227.2 KB) 1 12/2012
S02-02-02-32 CABLE JOINTING & TERMINATION RAYCHEM JOINTING INSTRUCTIONS 11KV 3C 400SQ.MM SCREENED PILC TO 11KV 3X1C 400SQ.MM XLPE (189.0 KB) 1 12/2012
S02-02-02-34 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C, 300 & 400SQ.MM AL SCREENED PILC (173.6 KB) 1 12/2012
S02-02-02-35 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C, 300 & 400SQ.MM ALSCREENED PILC (174.1 KB) 1 12/2012
S02-02-02-36 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C, 300 & 400SQ.MM AL SCREENED PILC (124.2 KB) 1 12/2012
S02-02-02-37 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C, 50 & 185SQ.MM CU BELTED PILC. (180.3 KB) 1 12/2012
S02-02-02-38 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C, 50 & 185SQ.MM CU BELTED PILC (153.3 KB) 1 12/2012
S02-02-02-39 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 11KV 3C, 50 & 185SQ.MM CU BELTED (327.8 KB) 1 12/2012
S02-02-02-40 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 22KV 3C 25, 120 & 240SQ.MM CU SCREENED PILC (212.0 KB) 1 12/2012
S02-02-02-41 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 22KV 3C 25, 120 & 240SQ.MM CU SCREENED PILC (224.7 KB) 1 12/2012
S02-02-02-42 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 22KV 3C 25, 120 & 240SQ.MM CU SCREENED PILC (200.1 KB) 1 12/2012
S02-02-02-43 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 22KV 3C 240SQ.MM SCREENED PILC TO 22KV 1C 240SQ.MM CU XLPE (184.1 KB) 1 12/2012
S02-02-02-44 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 22KV 3C 240SQ.MM CU SCREENED PILC TO 22KV 1C 240SQ.MM CU XLPE. (203.5 KB) 1 12/2012
S02-02-02-45 CABLE JOINTING & TERMINATIONS RAYCHEM JOINTING INSTRUCTIONS 22KV 3C 240SQ.MM SCREENED PILC TO 22KV 1C 240SQ.MM CU XLPE (204.2 KB) 1 12/2012
S02-02-02-46 CABLE JOINTING & TERMINATIONS SIGMAFORM TERMINATION INSTRUCTIONS 11KV XLPE (163.7 KB) 1 12/2012
S02-02-02-47 CABLE JOINTING & TERMINATIONS SIGMAFORM TERMINATION INSTRUCTION 22KV XLPE (172.5 KB) 1 12/2012
S02-02-02-49 CABLE JOINTING & TERMINATION RAYCHEM CABLE JOINING KIT FOR SINGLE CORE CABLE WITH (846.2 KB) 1 12/2012
Drawing Title Amendment # Amendment Date
S02-02-06-04 PACKAGE SUBSTATION 50KVA 11KV SINGLE PHASE FOUNDATION DETAILS (1.8 MB) 4 04/2019
S02-02-06-05 BBC SWITCHGEAR SUPPORT FOUNDATION DETAILS (181.9 KB) 4 12/2012
S02-02-06-06 RING MAIN UNIT CRAWFORD FOUNDATION DETAILS (1.7 MB) 4 04/2019
S02-02-06-07 RING MAIN UNT LUCY FOUNDATION DETAILS (1.6 MB) 4 04/2019
S02-02-06-08 RING MAIN UNIT REYROLLE ROSS FOUNDATION DETAILS (1.7 MB) 2 04/2019
S02-02-06-11 PACKAGE SUBSTATION 50KVA 11KV SINGLE PHASE CABLE AND TRENCH ARRANGEMENT (2.0 MB) 8 04/2019
S02-02-06-13 INDOOR SUBSTATION 1000KVA MAXIMUM CONSTRUCTION DETAILS (1.8 MB) 9 07/2021
S02-02-06-21 CIVIL CHAINWIRE MESH SECURITY FENCE WITHOUT TOP AND BOTTOM RAILS (240.1 KB) 1 12/2018
S02-02-06-24 CIVIL RING MAIN UNIT 3 WAY RM6 FOUNDATION DETAIL (45.9 KB) 2 10/2008
S02-02-06-25 CIVIL RING MAIN UNIT ABB SAFE RING FOUNDATION DETAIL (82.2 KB) 1 12/2012
S02-02-06-26 CIVIL TRENCH SECTION IN FOOTPATH CONCRETE ENCASED (507.7 KB) 2 05/2020
S02-02-06-29 CIVIL KIOSK SUBSTATION (300-1000KVA) CABLE ENTRY AND FOUNDATION DETAILS (4.9 MB) 4 11/2020
S02-02-06-30 CIVIL PACKAGE SUBSTATION MK2 CABLE ENTRY AND FOUNDATION DETAILS GREENFIELD INSTALLATION (4.3 MB) 3 01/2020
S02-02-06-31 CIVIL, MK2 PACKAGE SUBSTATION CABLE ENTRY AND FOUNDATION DETAILS (9.9 MB) 5 05/2020
S02-02-06-42 MK3 PACKAGE SUBSTATION CABLE ENTRY AND FOUNDATION DETAILS WITH MK2 SLAB (86.7 KB) 2 09/2023
S02-02-06-43 MK3 PACKAGE SUBSTATION CONDUIT LOCATION JIG WITH MK2 SLAB (3.1 MB) 3 09/2023
S02-02-06-46 CIVIL PROPOSED NEW SUBDIVISION NON-STANDARD STORMWATER LOCAL ROAD CROSSING NOTES AND DETAILS (248.7 KB) 1 05/2020
Drawing Title Amendment # Amendment Date
S02-02-08-01 LOW VOLTAGE COMPARTMENT GENERAL ARRANGEMENT (58.6 KB) 2 02/2021
S02-02-08-02 PACKAGE SUBSTATIONS HIGH VOLTAGE ARRANGEMENT (281.0 KB) 6 12/2012