Drawing No Drawing Title Amdt
S01-1-1-07 Line 9.0m Bolted Connections Type 2
S01-1-1-08 Line 10.5m Bolted Connections Type 2
S01-1-1-09 Line 12.0m Bolted Connections Type 2
S01-1-1-10 Line 13.5m Bolted Connections Type 2
S01-1-1-11 Line 10.5D Equivalent Bolted Connections Type 1
S01-1-1-12 Line 12.0D Equivalent Bolted Connections Type 1
S01-1-1-13 Line 13.5D Equivalent Bolted Connections Type 1
S01-1-1-14 Line 16.5D Bolted Connections Type 2
S01-1-1-15 Line 18.5D Bolted Connections Type 2
S01-1-1-17 Line 16.5D Jointed, Bolted Connections Type 0
S01-1-1-18 Line 16.5D Flange Jointed, Bolted Connections Type 0
S01-1-1-19 Line 18.5D Flange Jointed, Bolted Connections Type 0
S01-1-1-22 Line 15.0B & 15.0C, Bolted Connections Type 0
S01-1-1-23 Line 15.0D Equivalent, Bolted Connections Type 0
Crossarms
Drawing No Drawing Title Amdt
S01-1-2-08 High Impulse Replacement Crossarm And Brace 3
S01-1-2-10 HV Bolted Connections for Universal Pole Construction 2
S01-1-2-11 LV Bolted Connections for Universal Pole Construction 0
S01-1-2-12 Transformer and Cable Termination Bolted Connections for Universal Pole Construction 3
S01-1-2-13 Crossarm and Aerial Risers for Overhead Earth for Universal Pole Construction 1
S01-1-2-14 Steel Replacement For Timber Crossarm Type "X" And Delta Centre Phase 1
S01-1-2-15 HV Suspension Construction 1
S01-1-2-18 Line - Riser (Max. 5Degrees Deviation), Bolted Crossarm Attachment To Welded Poles 1
S01-1-2-19 Typical Bolted Arrangements For Connecting To Pre Bolted Poles 2
Line Hardware
Drawing No Drawing Title Amdt
S01-1-4-37 HV Shackle Straps Including 'B Top' for Universal Pole Construction 1
S01-1-4-38 Crossarm Brace and Details for Universal Pole Construction 3
S01-1-4-39 ABS Sidebreak Poletop Mounting for Universal Pole Construction 0
S01-1-4-40 Eye Nuts for Stays Typical Guy Details for Universal Pole Construction 1
S01-1-4-41 Eye Nuts for Terminations Typical Details for Universal Pole Construction 1
S01-1-4-42 ABS Downrod Mounting Bracket Adaptor for Universal Pole Construction 1
S01-1-4-44 Studs For 22kV Insulators 0
S01-1-4-45 Suspension Construction - Eyebolts for Universal Pole Construction 0
S01-1-4-46 Channel Spacer for T/F up to 50kVA, Bolted Connections 0
Earthing
Drawing No Drawing Title Amdt
S01-1-5-09 Earth Test Link for Universal Pole Construction 0
Assemblies
Drawing No Drawing Title Amdt
S01-2-1-12 Service Termination - Double Insulated, Bolted Connections 1
S01-2-1-17 Insulators on HV 'A Top' for Universal Pole Construction 0
S01-2-1-18 Insulators on HV 'B Top' for Universal Pole Construction 0
S01-2-1-19 Insulators on LV 'a Top' for Universal Pole Construction 0
S01-2-1-20 Insulators on LV 'c Top' for Universal Pole Construction 0
S01-2-1-21 Insulators on LV 'b Top' for Universal Pole Construction 0
S01-2-1-22 Overhead Earth Wire Line Pole for Universal Pole Construction 0
S01-2-1-23 Overhead Earth Wire Termination and Deviation Pole for Universal Pole Construction 0
S01-2-1-24 Overhead Earth Wire Insulators on HV 'B Top' for Universal Pole Construction 0
S01-2-1-25 Pole Top Units Vertical Angle for Universal Pole Construction 0
S01-2-1-26 Alley Arm for Universal Pole Construction 1
S01-2-1-27 Earthing CMEN Underslung Earth for Universal Pole Construction 0
S01-2-1-29 LV - ABC - Bolted Connections, 1 - 2 Services, Intermediate Suspension 0
S01-2-1-30 LV - ABC - Bolted Connections, 3 - 4 Services, Intermediate Suspension 0
S01-2-1-31 LV - ABC - Bolted Connections, Link Pole - Open Joint 0
S01-2-1-32 LV - ABC - Bolted Connections, Suspension Tee Off 0
S01-2-1-33 LV - ABC - Bolted Connections, Street Light Short Outreach,Intermediate Suspension 0
S01-2-1-34 LV - ABC - Bolted Connections, Intermediate Suspension 0
S01-2-1-35 LV - ABC - Bolted Connections, Non - Tension Joint 0
S01-2-1-36 SF6 Gas Load Break Switch for Universal Pole Construction 3
S01-2-1-37 Suspension Construction 22kV for Universal Pole Construction 0
S01-2-1-43 Suspension Construction 22kV (Termination) for Universal Pole Construction 0
S01-2-1-44 LV - ABC - Bolted Connections, Street Lighting Attachment Details 0
S01-2-1-45 LV - ABC - Bolted Connections, Street Light Long Outreach,Intermediate Suspension 0
Pole Top Units
Drawing No Drawing Title Amdt
S01-2-2-32 Air Break Switch Horizontal Mount for Universal Pole Construction 0
S01-2-2-33 HV Types A, B and C for Universal Pole Construction 0
S01-2-2-34 LV Types a, b and c for Universal Pole Construction 0
S01-2-2-35 HV Transposition for Universal Pole Construction 0
Pole Structures
Drawing No Drawing Title Amdt
S01-2-5-24 Substation Single Pole for Bolted Connections 2
S01-2-5-25 HV Cable Termination for Universal Pole Construction 2
S01-2-5-27 HV Metering Bolted Connections Type 1
S01-2-5-29 Foundation, Ground Level Details 0
Substation
Drawing No Drawing Title Amdt
S01-2-6-12 Single Pole Typical Arrangement for Universal Pole Construction 3
Switchgear
Drawing No Drawing Title Amdt
S01-2-7-08 Air Break Switch Vertical Mount for Universal Pole Construction 1
Design Data
S01-4-1-21 Crossarm and Foundation Strength, Bolted Poles 0